Altivar 12

Enquiry Us

Description

1-phase supply voltage: 100…120 V 50/60 Hz
For 3-phase Output 200/240 V motors
Motor Line supply (input) Drive (output) Reference
Power indicated on plate
on plate (1)
Maximum line current Apparent power Power dissipated at nominal current (1) Nominal current In Max. transient current for
at 100 V at 120 V 60 s 2 s
kW HP A A kVA W A A A
0.18 0.25 6 5 1 18 1.4 2.1 2.3 ATV12H018F1
0.37 0.5 11.4 9.3 1.9 29 2.4 3.6 4 ATV12H037F1
0.75 1 18.9 15.7 3.3 48 4.2 6.3 6.9 ATV12H075F1

 

1-phase supply voltage: 200…240 V 50/60 Hz
For 3-phase Output 200/240 V motors
Motor Line supply (input) Drive (output) Reference
Power indicated on plate Maximum line current Apparent power Power dissipated at nominal current (1) Nominal current In Max. transient current for
at 200 V at 240 V 60 s 2 s
kW HP A A kVA W A A A
0.18 0.25 3.4 2.8 1.2 18 1.4 2.1 2.3 ATV12H018M2
0.37 0.5 5.9 4.9 2 27 2.4 3.6 4 ATV12H037M2
0.55 0.75 8 6.7 2.8 34 3.5 5.3 5.8 ATV12H055M2
0.75 1 10.2 8.5 3.5 44 4.2 6.3 6.9 ATV12H075M2
1.5 2 17.8 14.9 6.2 72 7.5 11.2 12.4 ATV12HU15M2
2.2 3 24 20.2 8.4 93 10 15 16.5 ATV12HU22M2

 

3-phase supply voltage: 200…240 V 50/60 Hz
For 3-phase Output 200/240 V motors
Motor Line supply (input) Drive (output) Reference
Power indicated on plate Maximum line current Apparent power Power dissipated at nominal current (1) Nominal current In Max. transient current for
at 200 V at 240 V 60 s 2 s
kW HP A A kVA W A A A
0.18 0.25 2 1.7 0.7 16 1.4 2.1 2.3 ATV12H018M3
0.37 0.5 3.6 3 1.2 24 2.4 3.6 4 ATV12H037M3
0.75 1 6.3 5.3 2.2 41 4.2 6.3 6.9 ATV12H075M3
1.5 2 11.1 9.3 3.9 73 7.5 11.2 12.4 ATV12HU15M3
2.2 3 14.9 12.5 5.2 85 10 15 16.5 ATV12HU22M3
3 4 19 15.9 6.6 94 12.2 18.3 20.1 ATV12HU30M3
4 5.5 23.8 19.9 8.3 128 16.7 25 27.6 ATV12HU40M3