Description
Time delay auxiliary contact blocks for connection by screw clamp terminals | |||||
For use with TeSys D or tesys giga contactor Maximum number of auxiliary contact blocks that can be fitted per contactor, refer to TeSys catalogue. LADT0 and LADR0: with extended scale from 0.1 to 0.6 s. LADS2: with switching time of 40 ms ± 15 ms between opening of the N/C contact and closing of the N/O contact. |
|||||
Clip-on mounting |
No. of contacts |
Time delay | Reference | ||
Type | Setting range | ||||
Front | 1N/O + 1N/C | On-delay | 0.1…3 s 0.1…30 s 10…180 s 1…30 s |
LADT0 LADT2 LADT4 LADS2 |
|
Off-delay | 0.1…3 s 0.1…30 s 10…180 s |
LADR0 LADR2 LADR4 |
Time delay auxiliary contact blocks for connection by screw clamp terminals | ||||
Clip-on mounting |
Unlatching control |
For use on contactor |
Basic reference, complete with code indicating control circuit voltage (1) |
|
Front | Manual or electric |
LC1D09…D38 (ac or dc) LC1DT20…DT40 (ac or dc) LC1D40A…D65A 3P (ac or dc) LC1DT60A & DT85A 4P (ac or dc) |
LA6DK10● | |
LC1D80…D150 3P (ac) LC1D80 & D115 3P (dc) LC1D80 & D115 4P (ac) LP1D80 & LC1D115 4P (dc) |
LA6DK20● |
RC circuits (Resistor-Capacitor) | ||||
Effective protection for circuits highly sensitive to “high frequency interference” – For use in cases whereby voltage is virtually sinusoidal i.e. less than 5% total harmonic distortion – Voltage limited to 3 Uc max, oscillating frequency limited to 400 Hz max – Slight increase in drop-out time (1.2 to 2 times the normal time) |
||||
Mounting | For use with contactor | Reference | ||
Rating | Type a.c. |
|||
Clip-on side mounting (3) |
LC1D09…D38 (3P) LC1DT20…DT40 (4P) |
24…48 110…250 |
LAD4RCE LAD4RCU |
|
Clip-on side mounting (3) |
LC1D40A…D65A (3P) LC1DT60A…DT80A (4P) |
24…48 110…250 |
LAD4RC3E LAD4RC3U |
|
Screw fixing (4) | LC1D80…D150 (3P) LC1D40…D115 (4P) |
110…250 | LA4DA2U |
(1) Standard control circuit voltages.
Volts 50/60 Hz, | 24 | 110/127 | 220/240 |
Code | B | F | M |
(2) The mechanical latching block must not be powered up at the same time as the contactor.
The duration of the control signal for the mechanical latching block and the contactor should be:
≥ 100 ms for contactor operating on a.c. supply
≥ 250 ms for contactor operating on d.c. supply
(3) Clipping-on makes the electrical connection – overall size of the contactor remains unchanged
(4) Mounting at the top of the contactor on coil terminals A1 and A2
For 3-Pole reversing contactors for motor control | ||||
Contactor with screw clamp terminals or connectors. Horizontally mounted, assembled by customer | ||||
Kits for assembly of reversing contactors | ||||
Description | For contactors | Reference | ||
(2 identical contactors) | ||||
mechanical interlock LAD9V2 electrical interlock LAD9V1 power connection LAD9V5 (parallel) power connection LAD9V6 (reversing) |
LC1D09 TO D38 | LAD9R1V | ||
mechanical interlock LAD9V2 power connection LAD9V5 (parallel) power connection LAD9V6 (reversing) |
LC1D09 TO D38 | LAD9R1 | ||
mechanical interlock LAD4CM power connection LA9D65A69 |
LC1D40A TO D65A | LAD9R3 | ||
Kits for assembly of reversing contactors | ||||
mechanical interlock with integral electrical interlocking |
LC1D80 and D95 (ac) LC1D80 and D95 (dc) LC1D115 and D150 |
LA9D4002 LA9D8002 LA9D11502 |
||
mechanical interlock without integral electrical interlocking |
LCD09 to D38 LC1D40A to 65A LC1D80 and D95 (ac) LC1D80 and D95 (dc) |
LAD9V2 LAD4CM LA9D50978 LA9D80978 |
||
Sets of power connections | ||||
Comprising of -set of parallel bars -set of reverser bars |
LC1D09 to D38 (screw clamp terminals) |
LAD9V5 LAD9V6 |
||
LC1D09 to D32 (spring terminals) |
LAD9V12 | |||
LC1D40A to D65A LC1D80 and D95 (ac & dc) LC1D115 and D150 |
LA9D65A69 LA9D8069 LA9D11569 |
For 4-Pole changeover contactor pairs | ||||
Contactor with screw clamp terminals or connectors. Horizontally mounted, assembled by customer | ||||
Kits for assembly of changeover pairs | ||||
Description | For contactors | Reference | ||
(2 identical contactors) | ||||
mechanical interlock LAD9V2 electrical interlock LAD9V1 power connection (changeover) LAD9V7 |
LC1DT20 TO DT40 screw clamps or connectors |
LADT9R1V | ||
mechanical interlock LAD9V2 power connection (changeover) LAD9V7 |
LC1DT20 TO DT40 screw clamps or connectors |
LAD9R1 | ||
mechanical interlock LAD9V2 power connection (changeover) LAD9V7 |
LC1DT20 TO DT40 screw clamps or connectors |
LADT9R1 | ||
Mechanical Interlocks | ||||
mechanical interlock with integral electrical interlocking |
LC1D80004 LP1D80004 LC1D115004 |
LA9D4002 LA9D8002 LA9D11502 |
||
mechanical interlock without integral electrical interlocking |
LC1DT20 TO DT40 LC1DT60A TO DT80A LC1D80004 LP1D80004 |
LAD9V2 LAD4CM LA9D50978 LA9D80978 |
||
Sets of power connections | ||||
set of parallel bars | LC1D80004 LP1D80004 LC1D115004 |