Description
◼Double-circuit type of limit switch
◼High mechanical strength, mainly consists of aluminum cast
◼Water-proof and oil-proof construction
◼Various actuators for different applications
◼Built-in contact box with double spring mechanism, longer mechanical life
Ratings
| Rated Voltage | Noninductive Load (A) | Inductive Load (A) | ||||||
| Resistance Load | Lamp Load | Inductive Load | Motor Load | |||||
| NC | NO | NC | NO | NC | NO | NC | NO | |
| 125VAC | 10 | 3 | 1.5 | 10 | 5 | 2.0 | ||
| 250VAC | 5 | 2 | 1 | 5 | 3 | 1.0 | ||
| 480VAC | 3 | 1.5 | 0.8 | 3 | 1.5 | 0.8 | ||
| 600VAC | 1 | 1 | 0.5 | 1.5 | 1 | 0.5 | ||
| 8VDC | 10 | 6 | 3 | 10 | 6 | |||
| 14VDC | 10 | 6 | 3 | 10 | 6 | |||
| 30VDC | 6 | 4 | 3 | 6 | 4 | |||
| 125VDC | 0.8 | 0.2 | 0.2 | 0.8 | 0.2 | |||
| 250VDC | 0.4 | 0.1 | 0.1 | 0.4 | 0.1 | |||
NOTES:
1.Inductive load has a power factor of 0.4 min.(AC) and a time constant of 7 msec.max.(DC).
2.Lamp load has an inrush current of 10 times the steady-state current,while motor load has an inrush current of 6 times the steady-state current.
3.Product with spring, its usable range of operating part is within one third of the whole spring length from the front end of spring.
|
Operation speed |
1mm-1m/s |
|
Operating frequency |
Electical: 30 operations/min |
|
Contact resistance |
25mΩ max. (initial value) |
|
Insulation resistance |
100mΩ min. (below 500VDC) |
|
Dielectric strength |
1500VAC, 50/60 Hz for 1 minute between current-carrying and non–current-carrying metal parts |
|
1500VAC, 50/60 Hz for 1 minute between current-carrying and non–current-carrying metal parts |
|
|
1500VAC, 50/60 Hz for 1 minute between each terminal and ground |
|
|
Vibration |
10-55Hz,1.5mm double amplitude |
|
Shock |
Mechanical durable: 1, 000m/Sec2 (about 100G’S)
Malfunction: 300m/Sec2 (about30G’S)
|
|
Ambient temperature |
Using:-20~+80℃(With no icing) |
|
Humidity |
<95% RH |
|
Electrical life |
500,000 operations above |
|
Protection level |
IP66 |
Operating Characteristics
| Model | CWL | CWLCA2-2 | CWLD2 | CWLNJ | CWLNJ-S2 | CWLCA12-2-Q
CWLCA12-2-QD |
CWLCL | CWLCA32-41
CWLCA32-42 |
CWLD | CWLNJ-2 | CWLNJ-30 | CWLD1 | CWLD3 |
| operating
Force |
OF(Max) | 1360g | 2720g | 150g | 29g | 1360g | 142g | 1200g | 2720g | 120g | 80g | 2720g | 2720g |
| Release
Force |
RF(Min.) | 227g | 910g | 227g | 28g | – | 910g | – | – | 910g | 910g | ||
| pre-Travel | PT(Max.) | 20° | 1.7mm | 28mm | 28mm | 20° | 20° | 55° | 1.7mm | 28mm | 28mm | 1.7mm | 1.7mm |
| overTravel | OT(Min.) | 30° | 5.6mm | – | – | 30° | 30° | 35° | 6.4mm | – | – | 5.6mm | 5.6mm |
| Movement
Diferential |
MD(Max.) | 12° | 1mm | – | – | 12° | 12° | – | 1mm | – | – | 1mm | 1mm |
| Total Force | TF(Max.) | 2720g | – | – | – | 2720g | 200g | – | – | – | – | 2720g | 2720g |
| Total Travel | TT(Min.) | 50° | 6.5 ±0.8mm | – | – | 50° | 50° | OP:90±10 ° | Op:34 ±2.8mm | – | – | 6.5±0.8mm | 9±0.8mm |
| Model | Appearance | Dimension |
| CWLCA2-2 | ![]() ![]() |
![]() ![]() |
| CWLCA12-2-Q | ![]() ![]() |
![]() ![]() |
| CWLCA12-2-QD | ![]() ![]() |
![]() ![]() |
| CWLCA32-41 | ![]() ![]() |
![]() ![]() |
| CWLCA32-41/M | ![]() ![]() |
![]() ![]() |
| CWLCA32-42 | ![]() ![]() |
![]() ![]() |
| CWLCA32-42/M | ![]() ![]() |
![]() ![]() |
| CWLCL | ![]() ![]() |
![]() ![]() |
| CWLD | ![]() ![]() |
![]() ![]() |
| CWLD1 | ![]() ![]() |
![]() ![]() |
| CWLD2 | ![]() ![]() |
![]() ![]() |
| CWLD3 | ![]() ![]() |
![]() ![]() |
| CWLNJ | ![]() ![]() |
![]() ![]() |
| CWLNJ-2 | ![]() ![]() |
![]() ![]() |
| CWLNJ-30 | ![]() ![]() |
![]() ![]() |
| CWLNJ-S2 | ![]() ![]() |
![]() ![]() |