DOL motor starter using thermal overload relays

Enquiry Us

Description

DOL starters, non-reversing
This combination comprises of:
■ One 3-Pole EasyPact TVS contactor
■ One overload relay
Short-circuit protection is provided by separate magnetic motor protection circuit breaker/fuse protection
Please see EasyPact TVS catalogue for more information
Standard power
rating of 3-phase
motors 50/60Hz
in AC3
400V
Combination comprises of:
Contactor
Basic reference
complete with
code (1)
Thermal
overload relay
Reference
Setting range
kW A A
0.06 0.2 LC1E06•••• LRE02 0.16 – 0.25
0.09 0.3 LC1E06••••
LC1E06••••
LRE03
LRE04
0.25 – 0.40
0.40 – 0.63
0.12
0.18
0.37
0.55
0.44
0.6
1.1
1.5
LC1E06••••
LC1E06••••
LC1E06••••
LC1E06•••
LRE05
LRE05
LRE06
LRE06
0.63 -1.0
0.63 -1.0
1.0 -1.6
1.0 -1.6
1.1
1.5
2.2
3
4
5.5
7.5
9
11
15
18.5
22
30
2.7
3.6
4.9
6.5
8.5
11.5
15.5
18.1
22
29
35
41
55
LC1E06••••
LC1E06••••
LC1E06••••
LC1E09••••
LC1E09••••
LC1E12••••
LC1E18••••
LC1E25••••
LC1E25••••
LC1E32••••
LC1E40••
LC1E50••
LC1E65••
LRE08
LRE08
LRE10
LRE12
LRE14
LRE16
LRE21
LRE22
LRE22
LRE32
LRE355
LRE357
LRE359
2.5 – 4.0
2.5 – 4.0
4.0 – 6.0
5.5 – 8.0
7.0 – 10
9.0 – 13
12 – 18
16 – 24
16 – 24
23 – 32
30 – 40
37 – 50
48 – 65
37 66 LC1E80••
LC1E80••
LRE361
LRE363
55 – 70
63 – 80
45
55
75
90
110
132
160
200
250
335
80
97
132
160
195
250
280
350
430
574
LC1E95••
LC1E120••
LC1E160••
LC1E200••
LC1E250••
LC1E250••
LC1E300••
LC1E400••
LC1E500••
LC1E630••
LRE365
LRE482
LRE483
LRE483
LRE484
LRE484
LRE486
LRE487
LRE488
LRE489
80 – 104
84 – 135
124 – 198
124 – 198
146 – 234
146 – 234
208 – 333
259…414
321…513
394…630
Accessories for reversing motor starter assembly
Contactors with screw clamp terminals
Using 2 identical contactors Set of power
connections
Mechanical interlock
Mechanical interlock Reference Reference
LC1E06…E12
LC1E18/E25
LC1E32/E38
LC1E40…E65
LC1E80/E95
LC1E120/E160
LC1E200/E250
LC1E300…E500
LC1E630
LAEP1
LAEP12
LAEP2
LAEP3
LAEP4
DIY(1)
DIY(1)
DIY(1)
DIY(1)
LAEM1
LAEM1
LAEM1
LAEM1
LAEM4
LAEM5
LAEM6
LAEM7
LAEM8
Instantaneous auxiliary contact blocks for connection
by screw lamps terminals
– For use in normal operating environment
Clip-on mounting Number of contacts
per block
Reference
Front 1 NO / 1 NC
2 NO
2 NC
2 NO / 2 NC
LAEN11
LAEN20
LAEN02
LAEN22
Time delay auxiliary contact blocks for connection by screw clamp
terminals 8 A – 690 V
– For use in normal operating environment
Clip-on
mounting (2)
Number of
contacts
per block
Time delay
Type
Setting
range
Reference
Front 1 NO / 1 NC  On-delay 1…30 s LAETSD
Auxiliary contact blocks, add-on modules and accessories.
(1) Standard control circuit voltages. For other voltages please refer to catalogue.
a.c. supply
Volts 24 48 110 220 240 380 415 440
LC1E06…300
50Hz
60Hz
B5
B6
E5
F5
F6
M5
M6
U5
Q5
Q6
N5
R5
R6
LC1E400…630
50/60 Hz E7 F7 M7 U7 Q7 N7 R7
2) LC1E06 to E65: clip-on mounting on 35 mm 5 rail AM1 DP or screw fixing.
LC1E80 to E95: clip-on mounting on 35 mm rail AM1DP or 75 mm rail AM1 DL or screw fixing.
LC1E120 and E160: clip-on mounting on 2 x 35 mm 5 rail AM1 DP or screw fixing.