Description
For 3-Pole reversing contactors for motor control | |||||
• Compensated relays with manual or automatic reset, • with relays trip indicator, • for a.c. or d.c. |
|||||
Relay setting range |
Fuses to be used with selected relays | For use with contactor LC1 |
Reference | ||
A | aM A |
gG A |
BS88 A |
||
Class 10A with connection by screw clamp terminals | |||||
0.10…0.16 0.16…0.25 0.25…0.40 0.40…0.63 0.63…1 1…1.6 1.6…2.5 2.5…4 4…6 5.5…8 7…10 9…13 12…18 16…24 23…32 30…38 |
0.25 0.5 1 1 2 2 4 6 8 12 12 16 20 25 40 50 |
2 2 2 2 4 4 6 10 16 20 20 25 35 50 63 80 |
– – – – – 6 10 16 16 20 20 25 32 50 63 80 |
D09…D38 D09…D38 D09…D38 D09…D38 D09…D38 D09…D38 D09…D38 D09…D38 D09…D38 D09…D38 D09…D38 D12…D38 D18…D38 D25…D38 D25…D38 D32 and D38 |
LRD01 LRD02 LRD03 LRD04 LRD05 LRD06 LRD07 LRD08 LRD10 LRD12 LRD14 LRD16 LRD21 LRD22 LRD32 LRD35 |
Class 10A with connection by Everlink BTR screw connectors | |||||
9…13 12…18 |
16 20 |
25 32 |
25 35 |
D40A…D65A D40A…D65A |
LRD313 LRD318 |
17…25 | 25 | 50 | 50 | D40A…D65A D80…D95 (1) |
LRD325 |
23…32 | 40 | 63 | 63 | D40A…D65A D80…D95 (1) |
LRD332 |
30…40 | 50 | 80 | 80 | D40A…D65A D80…D95 (1) |
LRD340 |
40 | 100 | 100 | D40A…D65A D80…D95 (1) |
LRD350 | |
48…65 | 50 | 100 | 100 | D50A…D65A D80…D95 (1) |
LRD365 |
62…80 | 80 | 125 | 125 | D80 | LRD380 |
Class 10A with connection by screw clamp terminals | |||||
55…70 63…80 80…104 80…104 95…120 110…140 80…104 95…120 110…140 |
80 80 100 125 125 160 100 125 160 |
125 125 160 200 200 250 160 200 250 |
125 125 160 160 200 200 160 200 200 |
D80…D95 D80…D95 D80…D95 D115 … D150 D115 … D150 D150 (2) (2) (2) |
LRD3361 LRD3363 LRD3365 LRD4365 LRD4367 LRD4369 LRD33656 LRD33676 LRD33696 |
(1) These LRD need to be independently mount with LAD96560 to be used with D80…D95
(2) Independent mounting of the contactor
Differential thermal overload relays for use with fuses or magnetic circuit-breakers GV2 L and GV3 L |
|||||
Relay setting range |
Fuses to be used with selected relays | For use with contactor LC1 |
Reference | ||
A | aM A |
gG A |
BS88 A |
||
Class 10A with connection by screw clamp terminals | |||||
0.4…0.63 0.63…1 1…1.6 1.6…2.5 2.5…4 4…6 5.5…8 7…10 9…13 12…18 17…24 23…32 |
1 2 2 4 6 8 12 12 16 20 25 40 |
2 4 4 6 10 16 20 20 25 35 50 63 |
– – 6 10 16 16 20 20 25 32 50 63 |
D09…D38 D09…D38 D09…D38 D09…D38 D09…D38 D09…D38 D09…D38 D09…D38 D12…D38 D18…D38 D25…D38 D25…D38 |
LRD04L LRD05L LRD06L LRD07L LRD08L LRD10L LRD12L LRD14L LRD16L LRD21L LRD22L LRD32L |
Class 20A (1) with connection by Everlink BTR screw connectors | |||||
17…25 | 32 | 50 | 50 | D40A…D65A D80…D95 (2) |
LRD325L |
23…32 | 40 | 63 | 63 | D40A…D65A D80…D95 (2) |
LRD332L |
30…40 | 50 | 80 | 80 | D40A…D65A D80…D95 (2) |
LRD340L |
37…50 | 63 | 100 | 100 | D40A…D65A D80…D95 (2) |
LRD350L |
48…65 | 80 | 125 | 125 | D50A…D65A D80…D95 (2) |
LRD365L |
Class 20A (1) with connection by screw clamp terminals | |||||
55…70 63…80 |
100 100 |
125 160 |
125 125 |
D80 … D95 D80 … D95 |
LR2D3561 LR2D3563 |
(1) Standard IEC 60947-4-1 specifies a tripping time for 7.2 times the setting current Ir:
Class 20A: between 6 and 20 seconds
(2) These LRD need to be independently mount with LAD96560 to be used with D80…D95
Electronic thermal overload relays For use with fuses or magnetic circuit breakers |
|||||
Relay setting range |
Fuses to be used with selected relays | For use with contactor LC1 |
Reference | ||
A | aM A |
gG A |
BS88 A |
||
Classes 5.10.20.30 selected for direct connection on TeSys D contactors or connection using connectors |
|||||
0.1…0.5 0.4…2 1.6…8 6.4…32 |
D09…D38 D09…D38 D09…D38 D09…D38 |
LR9D01 LR9D02 LR9D08 LR9D32 |
|||
Classes 5.10.20.30 selectable for connection using connectors | |||||
22…110 | LR9D110S | ||||
Classes 10 or 10A with connection using bars or connectors | |||||
60…100 90…150 |
100 160 |
160 250 |
D115…D150 D115…D150 |
LR9D5367 LR9D5369 |
|
Classes 20 with connection using bars or connectors | |||||
60…100 90…150 |
125 200 |
160 250 |
D115 … D150 D115 … D150 |
LR9D5567 LR9D5569 |
(1) Standard IEC 60947-4-1 specifies a tripping time for 7.2 times the setting current Ir:
Class 20A: between 6 and 20 seconds
(2) These LRD need to be independently mount with LAD96560 to be used with D80…D95