Description
| For 3-Pole reversing contactors for motor control | |||||
| • Compensated relays with manual or automatic reset, • with relays trip indicator, • for a.c. or d.c.  | 
|||||
| Relay setting range  | 
Fuses to be used with selected relays | For use with contactor LC1  | 
Reference | ||
| A | aM A  | 
gG A  | 
BS88 A  | 
||
| Class 10A with connection by screw clamp terminals | |||||
| 0.10…0.16 0.16…0.25 0.25…0.40 0.40…0.63 0.63…1 1…1.6 1.6…2.5 2.5…4 4…6 5.5…8 7…10 9…13 12…18 16…24 23…32 30…38  | 
0.25 0.5 1 1 2 2 4 6 8 12 12 16 20 25 40 50  | 
2 2 2 2 4 4 6 10 16 20 20 25 35 50 63 80  | 
– – – – – 6 10 16 16 20 20 25 32 50 63 80  | 
D09…D38 D09…D38 D09…D38 D09…D38 D09…D38 D09…D38 D09…D38 D09…D38 D09…D38 D09…D38 D09…D38 D12…D38 D18…D38 D25…D38 D25…D38 D32 and D38  | 
LRD01 LRD02 LRD03 LRD04 LRD05 LRD06 LRD07 LRD08 LRD10 LRD12 LRD14 LRD16 LRD21 LRD22 LRD32 LRD35  | 
| Class 10A with connection by Everlink BTR screw connectors | |||||
| 9…13 12…18  | 
16 20  | 
25 32  | 
25 35  | 
D40A…D65A D40A…D65A  | 
LRD313 LRD318  | 
| 17…25 | 25 | 50 | 50 | D40A…D65A D80…D95 (1)  | 
LRD325 | 
| 23…32 | 40 | 63 | 63 | D40A…D65A D80…D95 (1)  | 
LRD332 | 
| 30…40 | 50 | 80 | 80 | D40A…D65A D80…D95 (1)  | 
LRD340 | 
| 40 | 100 | 100 | D40A…D65A D80…D95 (1)  | 
LRD350 | |
| 48…65 | 50 | 100 | 100 | D50A…D65A D80…D95 (1)  | 
LRD365 | 
| 62…80 | 80 | 125 | 125 | D80 | LRD380 | 
| Class 10A with connection by screw clamp terminals | |||||
| 55…70 63…80 80…104 80…104 95…120 110…140 80…104 95…120 110…140  | 
80 80 100 125 125 160 100 125 160  | 
125 125 160 200 200 250 160 200 250  | 
125 125 160 160 200 200 160 200 200  | 
D80…D95 D80…D95 D80…D95 D115 … D150 D115 … D150 D150 (2) (2) (2)  | 
LRD3361 LRD3363 LRD3365 LRD4365 LRD4367 LRD4369 LRD33656 LRD33676 LRD33696  | 
(1) These LRD need to be independently mount with LAD96560 to be used with D80…D95
(2) Independent mounting of the contactor
| Differential thermal overload relays  for use with fuses or magnetic circuit-breakers GV2 L and GV3 L  | 
|||||
| Relay setting range  | 
Fuses to be used with selected relays | For use with contactor LC1  | 
Reference | ||
| A | aM A  | 
gG A  | 
BS88 A  | 
||
| Class 10A with connection by screw clamp terminals | |||||
| 0.4…0.63 0.63…1 1…1.6 1.6…2.5 2.5…4 4…6 5.5…8 7…10 9…13 12…18 17…24 23…32  | 
1 2 2 4 6 8 12 12 16 20 25 40  | 
2 4 4 6 10 16 20 20 25 35 50 63  | 
– – 6 10 16 16 20 20 25 32 50 63  | 
D09…D38 D09…D38 D09…D38 D09…D38 D09…D38 D09…D38 D09…D38 D09…D38 D12…D38 D18…D38 D25…D38 D25…D38  | 
LRD04L LRD05L LRD06L LRD07L LRD08L LRD10L LRD12L LRD14L LRD16L LRD21L LRD22L LRD32L  | 
| Class 20A (1) with connection by Everlink BTR screw connectors | |||||
| 17…25 | 32 | 50 | 50 | D40A…D65A D80…D95 (2)  | 
LRD325L | 
| 23…32 | 40 | 63 | 63 | D40A…D65A D80…D95 (2)  | 
LRD332L | 
| 30…40 | 50 | 80 | 80 | D40A…D65A D80…D95 (2)  | 
LRD340L | 
| 37…50 | 63 | 100 | 100 | D40A…D65A D80…D95 (2)  | 
LRD350L | 
| 48…65 | 80 | 125 | 125 | D50A…D65A D80…D95 (2)  | 
LRD365L | 
| Class 20A (1) with connection by screw clamp terminals | |||||
| 55…70 63…80  | 
100 100  | 
125 160  | 
125 125  | 
D80 … D95 D80 … D95  | 
LR2D3561 LR2D3563  | 
(1) Standard IEC 60947-4-1 specifies a tripping time for 7.2 times the setting current Ir:
Class 20A: between 6 and 20 seconds
(2) These LRD need to be independently mount with LAD96560 to be used with D80…D95
| Electronic thermal overload relays  For use with fuses or magnetic circuit breakers  | 
|||||
| Relay setting range  | 
Fuses to be used with selected relays | For use with contactor LC1  | 
Reference | ||
| A | aM A  | 
gG A  | 
BS88 A  | 
||
| Classes 5.10.20.30 selected for direct connection on TeSys D contactors or connection using connectors  | 
|||||
| 0.1…0.5 0.4…2 1.6…8 6.4…32  | 
D09…D38 D09…D38 D09…D38 D09…D38  | 
LR9D01 LR9D02 LR9D08 LR9D32  | 
|||
| Classes 5.10.20.30 selectable for connection using connectors | |||||
| 22…110 | LR9D110S | ||||
| Classes 10 or 10A with connection using bars or connectors | |||||
| 60…100 90…150  | 
100 160  | 
160 250  | 
D115…D150 D115…D150  | 
LR9D5367 LR9D5369  | 
|
| Classes 20 with connection using bars or connectors | |||||
| 60…100 90…150  | 
125 200  | 
160 250  | 
D115 … D150 D115 … D150  | 
LR9D5567 LR9D5569  | 
|
(1) Standard IEC 60947-4-1 specifies a tripping time for 7.2 times the setting current Ir:
Class 20A: between 6 and 20 seconds
(2) These LRD need to be independently mount with LAD96560 to be used with D80…D95




