Description
| For 3-Pole reversing contactors for motor control | |||||
| • Compensated relays with manual or automatic reset, • with relays trip indicator, • for a.c. or d.c. |
|||||
| Relay setting range |
Fuses to be used with selected relays | For use with contactor LC1 |
Reference | ||
| A | aM A |
gG A |
BS88 A |
||
| Class 10A with connection by screw clamp terminals | |||||
| 0.10…0.16 0.16…0.25 0.25…0.40 0.40…0.63 0.63…1 1…1.6 1.6…2.5 2.5…4 4…6 5.5…8 7…10 9…13 12…18 16…24 23…32 30…38 |
0.25 0.5 1 1 2 2 4 6 8 12 12 16 20 25 40 50 |
2 2 2 2 4 4 6 10 16 20 20 25 35 50 63 80 |
– – – – – 6 10 16 16 20 20 25 32 50 63 80 |
D09…D38 D09…D38 D09…D38 D09…D38 D09…D38 D09…D38 D09…D38 D09…D38 D09…D38 D09…D38 D09…D38 D12…D38 D18…D38 D25…D38 D25…D38 D32 and D38 |
LRD01 LRD02 LRD03 LRD04 LRD05 LRD06 LRD07 LRD08 LRD10 LRD12 LRD14 LRD16 LRD21 LRD22 LRD32 LRD35 |
| Class 10A with connection by Everlink BTR screw connectors | |||||
| 9…13 12…18 |
16 20 |
25 32 |
25 35 |
D40A…D65A D40A…D65A |
LRD313 LRD318 |
| 17…25 | 25 | 50 | 50 | D40A…D65A D80…D95 (1) |
LRD325 |
| 23…32 | 40 | 63 | 63 | D40A…D65A D80…D95 (1) |
LRD332 |
| 30…40 | 50 | 80 | 80 | D40A…D65A D80…D95 (1) |
LRD340 |
| 40 | 100 | 100 | D40A…D65A D80…D95 (1) |
LRD350 | |
| 48…65 | 50 | 100 | 100 | D50A…D65A D80…D95 (1) |
LRD365 |
| 62…80 | 80 | 125 | 125 | D80 | LRD380 |
| Class 10A with connection by screw clamp terminals | |||||
| 55…70 63…80 80…104 80…104 95…120 110…140 80…104 95…120 110…140 |
80 80 100 125 125 160 100 125 160 |
125 125 160 200 200 250 160 200 250 |
125 125 160 160 200 200 160 200 200 |
D80…D95 D80…D95 D80…D95 D115 … D150 D115 … D150 D150 (2) (2) (2) |
LRD3361 LRD3363 LRD3365 LRD4365 LRD4367 LRD4369 LRD33656 LRD33676 LRD33696 |
(1) These LRD need to be independently mount with LAD96560 to be used with D80…D95
(2) Independent mounting of the contactor
| Differential thermal overload relays for use with fuses or magnetic circuit-breakers GV2 L and GV3 L |
|||||
| Relay setting range |
Fuses to be used with selected relays | For use with contactor LC1 |
Reference | ||
| A | aM A |
gG A |
BS88 A |
||
| Class 10A with connection by screw clamp terminals | |||||
| 0.4…0.63 0.63…1 1…1.6 1.6…2.5 2.5…4 4…6 5.5…8 7…10 9…13 12…18 17…24 23…32 |
1 2 2 4 6 8 12 12 16 20 25 40 |
2 4 4 6 10 16 20 20 25 35 50 63 |
– – 6 10 16 16 20 20 25 32 50 63 |
D09…D38 D09…D38 D09…D38 D09…D38 D09…D38 D09…D38 D09…D38 D09…D38 D12…D38 D18…D38 D25…D38 D25…D38 |
LRD04L LRD05L LRD06L LRD07L LRD08L LRD10L LRD12L LRD14L LRD16L LRD21L LRD22L LRD32L |
| Class 20A (1) with connection by Everlink BTR screw connectors | |||||
| 17…25 | 32 | 50 | 50 | D40A…D65A D80…D95 (2) |
LRD325L |
| 23…32 | 40 | 63 | 63 | D40A…D65A D80…D95 (2) |
LRD332L |
| 30…40 | 50 | 80 | 80 | D40A…D65A D80…D95 (2) |
LRD340L |
| 37…50 | 63 | 100 | 100 | D40A…D65A D80…D95 (2) |
LRD350L |
| 48…65 | 80 | 125 | 125 | D50A…D65A D80…D95 (2) |
LRD365L |
| Class 20A (1) with connection by screw clamp terminals | |||||
| 55…70 63…80 |
100 100 |
125 160 |
125 125 |
D80 … D95 D80 … D95 |
LR2D3561 LR2D3563 |
(1) Standard IEC 60947-4-1 specifies a tripping time for 7.2 times the setting current Ir:
Class 20A: between 6 and 20 seconds
(2) These LRD need to be independently mount with LAD96560 to be used with D80…D95
| Electronic thermal overload relays For use with fuses or magnetic circuit breakers |
|||||
| Relay setting range |
Fuses to be used with selected relays | For use with contactor LC1 |
Reference | ||
| A | aM A |
gG A |
BS88 A |
||
| Classes 5.10.20.30 selected for direct connection on TeSys D contactors or connection using connectors |
|||||
| 0.1…0.5 0.4…2 1.6…8 6.4…32 |
D09…D38 D09…D38 D09…D38 D09…D38 |
LR9D01 LR9D02 LR9D08 LR9D32 |
|||
| Classes 5.10.20.30 selectable for connection using connectors | |||||
| 22…110 | LR9D110S | ||||
| Classes 10 or 10A with connection using bars or connectors | |||||
| 60…100 90…150 |
100 160 |
160 250 |
D115…D150 D115…D150 |
LR9D5367 LR9D5369 |
|
| Classes 20 with connection using bars or connectors | |||||
| 60…100 90…150 |
125 200 |
160 250 |
D115 … D150 D115 … D150 |
LR9D5567 LR9D5569 |
|
(1) Standard IEC 60947-4-1 specifies a tripping time for 7.2 times the setting current Ir:
Class 20A: between 6 and 20 seconds
(2) These LRD need to be independently mount with LAD96560 to be used with D80…D95