Adjustable hysteresis |
Undervoltage detection |
Overvoltage detection |
Stabilization time adjustable |
Tripping delay |
Version of auxiliary Contacts |
Measurable Line Voltage |
Order No. |
s | s | CO Contact | V | ||||
Monitoring of phase sequence | |||||||
Auto RESET | |||||||
— | — | — | — | — | 1 2 |
160….260 AC | 3UG4511-1AN20 3UG4511-1BN20 |
1 2 |
320….500 AC | 3UG4511-1AP20 3UG4511-1BP20 |
|||||
1 2 |
420…..690 AC | 3UG4511-1AQ20 3UG4511-1BQ20 |
|||||
Monitoring of phase sequence, phase failure and phase asymmetry | |||||||
Auto RESET, closed-circuit principle, unbalance threshold permanently 10% | |||||||
— | — | — | — | — | 1 2 |
160….690 AC | 3UG4512-1AR20 3UG4512-1BR20 |
Monitoring of phase sequence, phase failure, asymmetry and undervoltage | |||||||
Analogically adjustable, Auto RESET, closed-circuit principle, unbalance and undervoltage threshold permanently 20% |
|||||||
5% of set value | √ | — | — | 0.1…..20 | 2 | 160….690 AC | 3UG4513-1BR20 |
Digitally adjustable, Auto or Manual RESET, open-circuit or closed-circuit principle, asymmetry threshold 0 or 5…20% |
|||||||
Adjustable 1….20V | √ | — | 0.1…..20 | 0.1…..20 | 2 | 160….690 AC | 3UG4614-1BR20 |
Monitoring of phase sequence, phase failure, overvoltage and undervoltage | |||||||
Digitally adjustable, Auto RESET or Manual RESET, open-circuit or closed-circuit principle | |||||||
Adjustable 1….20V | √ | √ | — | 0.1…..20 | 2 | 160….690 AC | 3UG4615-1CR20 |
Monitoring of phase sequence, phase and N conductor failure, overvoltage and undervoltage | |||||||
Digitally adjustable, Auto RESET or Manual RESET, open-circuit or closed-circuit principle | |||||||
Adjustable 1….20V | √ | √ | — | 0.1…..20 | 2 | 90….400 AC against N |
3UG4616-1CR20 |
Automatic direction correction in case of wrong phase sequence, phase failure, phase unbalance, overvoltage and undervoltage |
|||||||
Digitally adjustable, Auto RESET or Manual RESET, open-circuit or closed-circuit principle unbalance threshold 0 or 5…20% |
|||||||
Adjustable 1….20V | √ | √ | — | 0.1…..20 | 2 | 160….690 AC | 3UG4617-1CR20 |
Automatic correction of the direction of rotation in case of wrong phase sequence, phase and N failure, phase asymmetry, overvoltage and undervoltage |
|||||||
Digitally adjustable, Auto RESET or Manual RESET, open-circuit or closed-circuit principle unbalance threshold 0 or 5…20% |
|||||||
Adjustable 1….20V | √ | √ | — | 0.1…..20 | 2 | 90….400 AC against N |
3UG4618-1CR20 |
Note:
√ Function available