Selection Table for Zelio Time – Timing Relays

Enquiry Us

Description

Selection Table
Selection Criteria
■ Functions (On-delay or Off-delay, counter, flashing…)
■ Supply voltage (example: a/c 12 V…240 V).
■ Timing range for a timing relay (example: 0.05 s…100 h) RPM power relays and accessories
■ Type of output (contact or solid state) and required Number of contacts.
■ Breaking capacity or Rated current of contacts, expressed in Amperes.
This is the maximum current which may flow through the contacts.
Functions Timing range Supply voltage Type of output Rated Relay=
A 0.1s… 100h 12V 2 CO contacts
4 CO contacts
5A REXL2TMJD
REXL4TMJD
24V 2 CO contacts
4 CO contacts
REXL2TMBD
REXL4TMBD
24V 2 CO contacts
4 CO contacts
REXL2TMB7
REXL4TMB7
120V 2 CO contacts
4 CO contacts
REXL2TMF7
REXL4TMF7
230V 2 CO contacts
4 CO contacts
REXL2TMP7
REXL4TMP7
24… 240V 1 solid state output 0.7 A RE17LAMW
RE17LAMWS
0.1s… 100h 24… 240V 24… 240V 5A RE48ATM12MW
A, Ac, At, B, Bw,
C, D, Di, H, Ht
0.1s… 100h 24… 240V 1 solid state output 0.7 A RE17LMBM
RE17LMBMS
12V
12… 240V
1 CO Relay 8 A RE17RMJU
RE17RMMW
RE17RMMWS
RE17RMMU
RE17RMMUS

2V
12… 240V
2 CO contacts RE22R2MMU
RE22R2MJU
RE22R2MMW
Selection Table
Functions Timing range Supply voltage Type of output Rated current Relay
A, At 0.1s…100 h 24 V/~ 24… 240 V 1 CO contact 8A RE17RAMU
RE17RAMUS
2 CO contacts RE22R2AMU
A, Aw 0.05s…300 h 24… 240 V 1 CO contact 8 A RE22R1AMR
2 CO contacts RE22R2AMR
A. At, Aw 0.05s.. 300 h 24… 240 V 1 CO contact 8A RE22R1MAMR
A, At, B, C, D, Di, H, Ht 0.1s…10h 24 V/ ~ 24… 240 V 1 CO contact 8A RE17RMEMU
RE17RMEMUS
A, B, C, Di 0.02s… 300 h 24… 240 V 2 CO contacts 5A RE48AML12MW
A, Ac, Ad, Ah, Ak, At, B, Bw, C, D, Di, Dt, 0.1s… 999 h 24… 240 V 2 CO contacts 8A RENF22R2MMW
Dit, H, Ht, L, Li, Lt, Lit, N, O, P, Pt, Qt, Qtt,
TI, Tt, W 8A
A, At, Aw, C, Ct, D, Dt, Dw, Di, Dit, Diw, H,

Ht, Hw, Qg, Qgt, Qt, Qtt, W, Wt

0.05s… 300 h 24… 240 V 2 CO contacts RE22R2MYMR
A, At, Aw, C, Ct, D, Dt, Dw, Di, Dit, Diw, H,

Ht, Hw, W, Wt, Ac, Act

0.05s… 300 h 24… 240 V 1 CO contact 8 A RE22R1MYMR
A1, A2, H1, H2 0.02s… 300 h 24… 240 V 2 CO contacts 5A RE48AMH13MW
Ac 0.05s… 300 h 24… 240 V 2 CO contacts 8A RE22R2ACMR
Ac, Act 0.05s… 300 h 24… 240 V 1 CO contact 8 A RE22R1ACMR
Ad, Ah, N, O, P, Pt, TI, Tt, W 0.1s… 100 h 24 V/~ 24… 240 V 1 CO contact 8A RE17RMXMU
RE17RMXMUS
2 CO contacts 8 A RE22R2MXMU
Ak, Akt 0.05s… 300 h 24… 240 V 1 CO contact 8A RE22R1AKMR
B 0.1s… 100 h 24 V/~ 24… 240 V 1 CO contact 8A RE17RBMU
RE17RBMUS
C 0.1s… 100 h 24… 240 V 1 solid state output 0.7A RE17LCBM
RE17LCBMS
24 V/~ 24… 240 V 1 CO contact 8A RE17RCMU
RE17RCMUS
0.05s… 300 h 24… 240 V 2 CO contacts 8A RE22R2CMR
C, Ct 0.05s… 300 h 24… 240 V 1 CO contact 8A RE22R1CMR
D, Dw 0.05s… 300 h 24… 240 V 1 CO contact 8A RE22R1DMR
2 CO contacts RE22R2DMR
H 0.1s… 100 h 24… 240 V 1 solid state output 0.7A RE17LHBM
RE17LHBMS
H, Hw 0.05s… 300 h 24…240 V 1 CO contact 8 A RE22R1HMR
2 CO contacts 8 A RE22R2HMR
H, Ht 0.1s… 100 h 24 V/~ 24… 240 V 1 CO contact 8A RE17RHMU
RE17RHMUS
K 0.05s… 10 min 24…240 V 1 CO contact

2 CO contacts

5A RE22R1KMR
RE22R2KMR
K, He 0.05s… 300 h 24…240 V 1 CO contact 5A RE22R1MKMR
L, Li 0.1s… 100 h 24 V/~ 24… 240 V 1 CO contact 8 A RE17RLMU
RE17RLMUS
24… 240 V 1 solid state output 0.7A RE17LLBM
RE17LLBMS
12 V 1 CO contact 8 A RE17RLJU
0.02s… 300 h 24… 240 V 2 CO contacts 5A RE48ACV12MW
L, Lt, Li, Lit 0.05s… 300 h 24… 240 V 1 CO contact 8 A RE22R1MLMR
Q 0.01s… 300 s 24 V/~ 24… 240 V 1 CO contact 8A RE22R1QMU
230…240 V, ~ 380……. V RE22R1QMQ
Qc 0.05s… 300 h 24 V, ~ 24……….. V 1 CO contact 8A RE22R1QCMU
Qe 0.3s… 30s 380…415 V 2 CO contacts 8A RE22R2QEMT
24… 240 V RE22R2QEMR
Qg 0.05s… 300 h 24… 240 V 2 CO contacts 8A RE22R2QGMR
Qt 0.05s… 300 h 24… 240 V 2 CO contacts 8 A RE22R2QTMR
W, Wt 0.05s… 300 h 24… 240 V 2 CO contacts 8 A RE22R2MWMR