Description
◼Double circuit type of limit switch
◼High mechanical strength, consists of intensive plastic and
aluminum cast
◼Water-proof and oil proof construction
◼Built-in contact box has double-spring and long mechanical life
◼Smooth operation with larger over travel distance
◼Various actuators for different application
Ratings
|  
 Rated Voltage  | 
Noninductive Load (A) | Inductive Load (A) | ||||||
| Resistance Load | Lamp Load | Inductive Load | Motor Load | |||||
| NC | NO | NC | NO | NC | NO | NC | NO | |
|  
 125VAC 250VAC 
  | 
5 5  | 
5 5  | 
1.5 1  | 
 
 0.7 0.5 
  | 
3 3  | 
3 3  | 
2 1.5  | 
1 0.8  | 
| 8VDC | 5 | 5 | 3 | 3 | 5 | 4 | 3 | 3 | 
| 14VDC | 5 | 5 | 3 | 3 | 4 | 4 | 3 | 3 | 
| 30VDC | 5 | 5 | 3 | 3 | 4 | 4 | 3 | 3 | 
| 125VDC | 0.4 | 0.4 | ||||||
| 250VDC | 0.2 | 0.2 | ||||||
| Inrush Current | N.C: below 24A, N.O: below 12A | |||||||
NOTES:
1.Inductive load has a power factor of 0.4 min.(AC) and a time constant of 7 msec.max.(DC).
2.Lamp load has an inrush current of 10 times the steady-state current,while motor load has an inrush current of 6 times the steady-state current.
3.Product with spring, its usable range of operating part is within one third of the whole spring length from the front end of spring.
| 
 Operation speed  | 
 5mm-0.5m/s  | 
| 
 Operating frequency  | 
 Electical: 30 operations/min  | 
| 
 Contact resistance  | 
 25mΩ max. (initial value)  | 
| 
 Insulation resistance  | 
 100mΩ min. (below 500VDC)  | 
| 
 Dielectric strength  | 
 1000VAC, 50/60 Hz for 1 minute between terminals of the same polarity  | 
| 
 1500VAC, 50/60 Hz for 1 minute between current-carrying and non–current-carrying metal parts  | 
|
| 
 1500VAC, 50/60 Hz for 1 minute between each terminal and ground  | 
|
| 
 Vibration  | 
 10-55Hz,1.5mm double amplitude  | 
| 
 Shock  | 
 Mechanical durable: 1, 000m/Sec2 (about 100G’S) Malfunction: 300m/Sec2 (about 30G’S)  | 
| 
 Ambient temperature  | 
 Using:-20~+70℃(With no icing)  | 
| 
 Humidity  | 
 <95% RH  | 
| 
 Electrical life  | 
 500,000 operations above  | 
| 
 Degree of protection  | 
 IP65  | 
Operating Characteristics
| Model | CSA | CSA-001 | CSA-003 | CSA-012 | CSA-021
 CSA-021M  | 
CSA-041 | CSA-031
 CSA-031M  | 
CSA-051 | CSA-061 | CSA-071 | CSA-081 | 
| Operating force | OF
 (Max.)  | 
800g | 800g | 800g | 400g | 400g | 400g | 400g | 150g | 150g | 150g | 
| Release force | RF
 (Min.)  | 
400g | 400g | 400g | 100g | 100g | 100g | 100g | 50g | 50g | 50g | 
| Pre-travel | PT
 (Max.)  | 
1.8mm | 1.8mm | 1.8mm | 20° | 20° | 20° | 20° | 30mm | 30mm | 30mm | 
| Tripping position | TP
 ±10%  | 
2.0mm | 2.0mm | 2.0mm | 22.5° | 22.5° | 22.5° | 22.5° | 22.5° | 22.5° | 22.5° | 
| Movement differential | MD
 (Max.)  | 
1.2mm | 1.2mm | 1.2mm | 10° | 10° | 10° | 10° | 14° | 14° | 14° | 
| Over travel | OT
 (Min.)  | 
4.0mm | 4.0mm | 4.0mm | 75° | 75° | 75° | 75° | 20mm | 20mm | 20mm | 
| Total travel | TT
 (Min.)  | 
5.8mm | 5.8mm | 5.8mm | 95° | 95° | 95° | 95° | 50mm | 50mm | 50mm | 
| Rotary indexing | 22.5° | 22.5° | 22.5° | 22.5° | 
| Model | Appearance | Dimension | 
| CSA-001 | ![]() ![]()  | 
![]() ![]()  | 
| CSA-003 | ![]() ![]()  | 
![]() ![]()  | 
| CSA-012 | ![]() ![]()  | 
![]() ![]()  | 
| CSA-021 | ![]() ![]()  | 
![]() ![]()  | 
| CSA-031 | ![]() ![]()  | 
![]() ![]()  | 
| CSA-041 | ![]() ![]()  | 
![]() ![]() ![]()  | 
| CSA-051 | ![]() ![]()  | 
![]() ![]() ![]()  | 
| CSA-061 | ![]() ![]()  | 
![]() ![]()  | 
| CSA-071 | ![]() ![]()  | 
![]() ![]()  | 
| CSA-081 | ![]() ![]()  | 
![]() ![]()  | 